The Most Inspiring dark field microscopy spirochetes Story of the Year

dark field microscopy spirochetes

How to change Dark Field Transformation?

How to change Dark Field Transformation?

Most stereo and standard compound microscopes have the potential for dark field microscopy.

If a microscope has built-in elements to easily modify for dark field illumination, the manufacturer usually lists this amongst the observation specifications.

You can achieve dark field by using condensers, mirrors and/or a “stop.” Some microscopes come with these accessories or researchers can purchase dark field kits, or even use some common items to adapt a microscope for dark field illumination.

In bright field illumination, the object is lit from below the stage, resulting in a larger, contrasted image that can be studied.

A dark field microscope blocks this central light with a condenser so that only oblique rays hit the object.

An Abbe condenser, for example, contains a concave orb that collects light rays in all azimuths that bounce off a sample to form a cone of illumination.

If there is nothing on the stage, the aperture of the condenser is greater than the objective and the view will be completely black.

A stop is an opaque object that blocks the central light when placed underneath the stage condenser.

This also causes light to scatter in all azimuths, resulting in a cone of light that allows for dark field observation.

Too expensive? What you can do…

If you do not have access to these accessories and cannot afford a dark field kit, there are alternative ways to adapt your microscope for dark field illumination.

The expensive stops are all made of opaque material.

Any possible substitutions cannot have any transparent properties.

One option is to use a circular object, such as a coin; adhere the coin to a larger disk and place below the stage.

You can also cut out a round piece of thick paper, such as construction paper, cardboard or poster-board, and attach to the condenser.

Whatever you use, the trick is to find the right diameter so that the makeshift stop will block the light and only allow the oblique rays to illuminate the specimen.

dark field microscopy spirochetes

When to use dark field microscopy spirochetes

When to use dark field microscopy spirochetes

Dark field illumination is most readily set up at low magnifications (up to 100x), although it can be used with any dry objective lens. Any time you wish to view everything in a liquid sample, debris and all, dark field is best. Even tiny dust particles are obvious. Dark field is especially useful for finding cells in suspension. Dark field makes it easy to obtain the correct focal plane at low magnification for small, low contrast specimens. Use dark field for

Initial examination of suspensions of cells such as yeast, bacteria, small protists, or cell and tissue fractions including cheek epithelial cells, chloroplasts, mitochondria, even blood cells (small diameter of pigmented cells makes it tricky to find them sometimes despite the color).
Initial survey and observation at low powers of pond water samples, hay or soil infusions, purchased protist or metazoan cultures.
Examination of lightly stained prepared slides. ? Initial location of any specimen of very small size for later viewing at higher power.
Determination of motility in cultures

dark field microscopy spirochetes

What does my scope need to do dark field?

What does my scope need to do dark field?

Most stereo and compound microscopes can do dark field imaging. Check your microscope’s specifications to see if this is your case. If your microscope does not have a built-in condenser or stop, don’t worry, you can probably still use your microscope for dark field imaging. You should be able to purchase an aftermarket condenser or even make your own stop. Read below to learn more about condensers and stops.

Condensers-In a dark field set-up, an Abbe dark field condenser is mounted below the microscope stage. This controls the light before it enters your specimen and objective. It’s made up of two uncorrected lenses and an iris diaphragm. The top lens of an Abbe dark field condenser is concave, therefore the light emerging from this top lens forms an inverted hollow cone of light. Subsequently, only oblique light rays reach your specimen. If the numerical aperture of your condenser is greater than your objective these oblique light rays will cross and miss your objective making the background appear dark while reflecting and refracting off your specimen. You can adjust your condenser for optimal brightness, contrast, depth of field, etc two different ways:1) By moving it closer or further away from the specimen and stage, or 2) By opening or closing its iris or diaphragm.

Stops-Stops are opaque discs located just under the bottom lens of the substage condenser. When using stops, both the aperture and field diaphragms need to be opened wide to allow oblique rays to diffuse around the stop and reach your specimen. (Think solar eclipse, where the stop is the moon blocking the earth/specimen from direct light.) You can purchase stops for almost any scope, or even make your own, by mounting a coin (or other opaque disc) on a clear glass disk.

When is dark field good to use?

Dark field is useful when you would like to view unstained, transparent specimens. The best specimens for dark field should have a refractive index that is close to the surroundings and otherwise difficult to image using conventional bright field microscopy. For example, many small aquatic organisms have refractive indices that are very similar to their surrounding water, making them ideal candidates for dark field microscopy. Other ideal biological candidates include diatoms, small insects, unstained live bacteria, yeast, tissue culture cells, etc. Non-biological candidates include mineral and chemical crystals, and thin sections of polymers.

dark field microscopy spirochetes

What is Disadvantages of dark field microscopy spirochetes?

What is Disadvantages of dark field microscopy spirochetes?

A dark field microscope can result in beautiful and amazing images; this technique also comes with a number of disadvantages.

First, dark field images are prone to degradation, distortion and inaccuracies.
A specimen that is not thin enough or its density differs across the slide, may appear to have artifacts throughout the image.
The preparation and quality of the slides can grossly affect the contrast and accuracy of a dark field image.
You need to take special care that the slide, stage, nose and light source are free from small particles such as dust, as these will appear as part of the image.
Similarly, if you need to use oil or water on the condenser and/or slide, it is almost impossible to avoid all air bubbles.
These liquid bubbles will cause images degradation, flare and distortion and even decrease the contrast and details of the specimen.
Dark field needs an intense amount of light to work. This, coupled with the fact that it relies exclusively on scattered light rays, can cause glare and distortion.
It is not a reliable tool to obtain accurate measurements of specimens.
Finally, numerous problems can arise when adapting and using a dark field microscope. The amount and intensity of light, the position, size and placement of the condenser and stop need to be correct to avoid any aberrations.

Dark field has many applications and is a wonderful observation tool, especially when used in conjunction with other techniques.

However, when employing this technique as part of a research study, you need to take into consideration the limitations and knowledge of possible unwanted artifacts.

dark field microscopy spirochetes

dark field microscopy spirochetes for point-of-care syphilis diagnosis

syphilis is a sexually transmitted disease caused by the spirochetal bacterium Treponema pallidum subspecies pallidum. Globally, an estimated 12 million cases of syphilis occur annually. In the United States, 13,997 cases of primary and secondary (infectious) syphilis were reported to the Centers for Disease Control and Prevention (CDC) in 2009, a 3.7% increase from 2008 and a 134% increase from 2000, when a post-war low of 5,979 primary and secondary syphilis cases was reported. Men who have sex with men (MSM) — especially those who are HIV infected — and blacks are disproportionately affected by syphilis. Geographically, urban areas and the Southeastern region of the United States have the highest rates.

Syphilis is most commonly transmitted by skin-to-skin (or mucous membrane) contact. Following exposure, the infection passes through the following stages:

Primary syphilis, characterized by a painless ulcer, called a chancre, usually develops three weeks after exposure (range 10 days to 90 days) at the site of inoculation. The chancre heals spontaneously after several weeks.

Secondary syphilis is most often characterized by a generalized rash that also resolves without treatment. Rash on the palms and soles can also occur, as can systemic manifestations such as fever, malaise, and lymphadenopathy. Given the widely variable nature of the rash and other manifestations of the disease, syphilis has acquired the moniker “The Great Imitator.”

Early (one year) latent syphilis, defined by the absence of signs or symptoms of disease and diagnosed by serologic evidence of infection.

Tertiary syphilis, which affects about a third of untreated patients and manifests with cutaneous, cardiovascular, or neurologic disease.

Syphilis can also be acquired in utero at any stage of pregnancy and lead to congenital syphilis. Routine syphilis screening and treatment in pregnant women has made congenital syphilis rare in the United States.

Approaches to syphilis diagnosis

Because T pallidum is too fragile an organism to be cultured in the clinical setting, diagnostic testing relies on two approaches: direct detection of the organism and indirect evidence of infection.
Syphilis – Treponema pallidum on darkfield.

Direct methods include darkfield microscopy, molecular assays to detect T pallidum DNA, and histopathologic examination of biopsies of skin or mucous membranes (which can also provide indirect evidence of infection, on the basis of patterns of inflammation in the tissue). Direct methods have the advantage, in some cases, of detecting infection before a patient has mounted a measurable antibody response that results in a reactive serologic test result.

dark field microscopy spirochetes allows visualization of live treponemes obtained from a variety of cutaneous or mucous membrane lesions, as follows.

In primary syphilis, the chancre teems with treponemes that can be seen with darkfield microscopy. The sensitivity of darkfield microscopy for the diagnosis of primary syphilis is approximately 80%. Darkfield sensitivity declines over time and can also decrease if the patient has applied topical antibiotics to the lesion(s). Of note, the mouth harbors normal non-pathogenic treponemes that are indistinguishable microscopically from T pallidum. Therefore, oral specimens cannot be used for darkfield microscopy because of the possibility of false-positive test results.

In secondary syphilis, mucous patches (as long as not oral) and condyloma lata (found in moist areas between body folds) are appropriate specimens for darkfield microscopy. Dry skin lesions usually do not contain sufficient organisms for darkfield testing.

In congenital syphilis, moist discharge from the nose (snuffles) and vesiculobullous lesions of the skin are high-yield specimen sources for darkfield testing.

Indirect methods of diagnosis include serologic testing of blood or cerebrospinal fluid (CSF) and detection of CSF abnormalities (elevated white blood cell count or protein) consistent with neurosyphilis. Serologic testing of blood involves demonstration of host antibody to either endogenous antigens (non-treponemal tests) or to antigens of T pallidum (treponemal tests). Non-treponemal tests, including the rapid plasma reagin test and the venereal disease research laboratory test, have historically been used as the initial screening tests for the serologic diagnosis of syphilis. If a patient’s non-treponemal test is reactive, confirmatory testing with a treponemal test is performed, using either the T pallidum particle agglutination test, the fluorescent treponemal antibody-absorbed test, or another treponemal test. A reactive treponemal test confirms the diagnosis of a new or previously treated case of syphilis. If the treponemal test is non-reactive, the positive non-treponemal test result is considered a biologic false-positive that is not diagnostic of syphilis. A newer algorithm that is gaini

dark field microscopy spirochetes