So, you gave principle of dark field microscopy in microbiology-ing a shot? Didn’t work out? 12 things to try next.

principle of dark field microscopy in microbiology

What is Disadvantages of principle of dark field microscopy in microbiology?

A dark field microscope can result in beautiful and amazing images; this technique also comes with a number of disadvantages.

First, dark field images are prone to degradation, distortion and inaccuracies.
A specimen that is not thin enough or its density differs across the slide, may appear to have artifacts throughout the image.
The preparation and quality of the slides can grossly affect the contrast and accuracy of a dark field image.
You need to take special care that the slide, stage, nose and light source are free from small particles such as dust, as these will appear as part of the image.
Similarly, if you need to use oil or water on the condenser and/or slide, it is almost impossible to avoid all air bubbles.
These liquid bubbles will cause images degradation, flare and distortion and even decrease the contrast and details of the specimen.
Dark field needs an intense amount of light to work. This, coupled with the fact that it relies exclusively on scattered light rays, can cause glare and distortion.
It is not a reliable tool to obtain accurate measurements of specimens.
Finally, numerous problems can arise when adapting and using a dark field microscope. The amount and intensity of light, the position, size and placement of the condenser and stop need to be correct to avoid any aberrations.

Dark field has many applications and is a wonderful observation tool, especially when used in conjunction with other techniques.

However, when employing this technique as part of a research study, you need to take into consideration the limitations and knowledge of possible unwanted artifacts.

principle of dark field microscopy in microbiology

What Advantages and Disadvantages about principle of dark field microscopy in microbiology?

What Advantages and Disadvantages about principle of dark field microscopy in microbiology?

No one system is perfect, and dark field microscopy may or may not appeal to you depending on your needs.

Some advantages of using a dark field microscope are:

Extremely simple to use
Inexpensive to set up (instructions on how to make your own dark field microscope are below)
Very effective in showing the details of live and unstained samples
Some of the disadvantages are:

Limited colors (certain colors will appear, but they’re less accurate and most images will be just black and white)
Images can be difficult to interpret to those unfamiliar with dark field microscopy
Although surface details can be very apparent, the internal details of a specimen often don’t stand out as much with a dark field setup.

Below are contrasting examples of dark field (left) versus bright field (right) illumination of lens tissue paper. Note how they both create a different style of image.

Dark field illumination Bright field illumination

Admit it, by now you’re curious to check out your own dark field! You can create one with minimal time and effort. Just read on…

principle of dark field microscopy in microbiology

principle of dark field microscopy in microbiology TECHNOLOGY:

 

Darkfield microscopy creates contrast in transparent unstained specimens such as living cells. It depends on controlling specimen illumination so that central light which normally passes through and around the specimen is blocked. Rather than light illuminating the sample with a full cone of light (as in brightfield microscopy) the condenser forms a hollow cone with light travelling around the cone rather than through it.

This form of illumination allows only oblique rays of light to strike the specimen on the microscope stage and the image is formed by rays of light scattered by the sample and captured in the objective lens. When there is no sample on the microscope stage the view is completely dark.

Care should be taken in preparing specimens as features above and below the plane of focus can also scatter light and compromise image quality (for example, dust, fingerprints). In general, thin specimens are better because the possibility of diffraction artifacts is reduced.

principle of dark field microscopy in microbiology

What is principle of dark field microscopy in microbiology?

 

All of us are quite familiar with the appearance and visibility of stars on a dark night, this despite their enormous distances from the Earth. Stars can be readily observed at night primarily because of the stark contrast between their faint light and the black sky.

Yet stars are shining both night and day, but they are invisible during the day because the overwhelming brightness of the sun “blots out” the faint light from the stars, rendering them invisible. During a total solar eclipse, the moon moves between the Earth and the sun blocking out the light of the sun and the stars can now be seen even though it is daytime. In short, the visibility of the faint star light is enormously enhanced against a dark background.

This principle is applied in darkfield (also called darkground) microscopy, a simple and popular method for making unstained transparent specimens clearly visible. Such objects often have refractive indices very close in value to that of their surroundings and are difficult to image in conventional brightfield microscopy. For instance, many small aquatic organisms have a refractive index ranging from 1.2 to 1.4, resulting in a negligible optical difference from the surrounding aqueous medium. These are ideal candidates for darkfield illumination.

Darkfield illumination requires blocking out of the central light which ordinarily passes through and around (surrounding) the specimen, allowing only oblique rays from every azimuth to “strike” the specimen mounted on the microscope slide. The top lens of a simple Abbe darkfield condenser is spherically concave, allowing light rays emerging from the surface in all azimuths to form an inverted hollow cone of light with an apex centered in the specimen plane. If no specimen is present and the numerical aperture of the condenser is greater than that of the objective, the oblique rays cross and all such rays will miss entering the objective because of their obliquity. The field of view will appear dark.

The darkfield condenser/objective pair illustrated in Figure 1 is a high-numerical aperture arrangement that represents darkfield microscopy in its most sophisticated configuration, which will be discussed in detail below. The objective contains an internal iris diaphragm that serves to reduce the numerical aperture of the objective to a value below that of the inverted hollow light cone emitted by the condenser. The cardioid condenser is a reflecting darkfield design that relies on internal mirrors to project an aberration-free cone of light onto the specimen plane.

When a specimen is placed on the slide, especially an unstained, non-light absorbing specimen, the oblique rays cross the specimen and are diffracted, reflected, and/or refracted by optical discontinuities (such as the cell membrane, nucleus, and internal organelles) allowing these faint rays to enter the objective. The specimen can then be seen bright on an otherwise black background. In terms of Fourier optics, darkfield illumination removes the zeroth order (unscattered light) from the diffraction pattern formed at the rear focal plane of the objective. This results in an image formed exclusively from higher order diffraction intensities scattered by the specimen.

The photomicrographs in Figure 2 illustrate the effects of darkfield and brightfield illumination on silica skeletons from a small marine protozoan (radiolarian) in a whole mount specimen. In ordinary brightfield, skeletal features of the radiolarian are not well defined and tend to be washed out in photomicrographs recorded either with traditional film or digitally captured. was taken in brightfield illumination with the condenser aperture diaphragm closed to a point where diffraction artifacts obscure some of the sample detail. This enhances specimen contrast at the expense of image distortion. Under darkfield illumination, more detail is present, especially in the upper portion of the organism, and the image acquires an apparent three-dimensional appearance. When a red filter is used in conjunction with a darkfield stop , the radiolarian takes on a colorful appearance that is more pleasing, although no additional detail is produced and there is even some reduction in image quality.

Specimens that have smooth reflective surfaces produce images due, in part, to reflection of light into the objective. In situations where the refractive index is different from the surrounding medium or where refractive index gradients occur (as in the edge of a membrane), light is refracted by the specimen. Both instances of reflection and refraction produce relatively small angular changes in the direction of light, allowing some to enter the objective. In contrast, some light striking the specimen is also diffracted, producing a 180-degree arc of light that passes through the entire numerical aperture range of the objective. The resolving power of the

principle of dark field microscopy in microbiology

What is principle of dark field microscopy in microbiology?

What is principle of dark field microscopy in microbiology?

Have you ever heard of a dark field microscope? While such a name may sound like a sci-fi gadget used to measure black holes, in reality it’s just a handy tool used to view certain types of translucent samples. The average microscope user may not know about the concept of dark field microscopy, yet it can shed new light on the old way of viewing specimens.
Most people who have survived a biology class know what a light field microscope is. This type of scope uses bright field illumination, meaning it floods the specimen with white light from the condenser without any interference. Thus the specimen shows up as a dark image on a light background (or white field if you will).

This type of unit works best with specimens that have natural color pigments. The samples need to be thick enough to absorb the incoming light; so staining is usually paired with this type of microscope.

Plankton illuminated with a dark field microscopeYet what if the specimen is light colored or translucent, like the plankton on the right? It certainly won’t stand out against a strong white background. Additionally, some specimens are just too thin. They cannot absorb any of the light that passes through them, so they appear invisible to the user. This is where the concept of dark field illumination comes in!

Rather than using direct light from the condenser, one uses an opaque disk to block the light into just a few scattered beams. Now the background is dark, and the sample reflects the light of the beams only. This results in a light colored specimen against a dark background (dark field), perfect for viewing clear or translucent details.

On a grand scale, the same thing happens every day when you look up at the sky. Do the stars disappear when it’s light out? Of course not! They’re still there, their brilliance blotted out by the mid-day sun.

If you’re still having a hard time visualizing this concept, think of a dusty room with the light on and the door open. You may feel the dust affecting your breathing, but you probably won’t see it flying through the air.

Now turn off the light and close the door to just a sliver, while leaving the light on in the adjacent room. If you look at that sliver of light coming through the door, you’ll see all sorts of dust motes suspended in it. You’re employing a similar principle when you use dark field illumination!