How to dark field condenser attachment The Right Way

dark field condenser attachment

What PRINCIPLE of dark field condenser attachment?

The compound microscope may be fitted with a dark field condenser that has a numerical aperture (resolving power) greater than the objective. The condenser also contains a dark-field stop. The compound microscope now becomes a dark-field microscope. Light passing through the specimen is diffracted and enters the objective lens, whereas undiffracted light does not, resulting in a bright image against a dark background. Objects are seen as light objects against a dark background.

dark field condenser attachment

dark field condenser attachment at High Magnifications

 

For more precise work and blacker backgrounds, you may choose a condenser designed especially for darkfield, i.e. to transmit only oblique rays. There are several varieties: “dry” darkfield condensers with air between the top of the condenser and the underside of the slide–and immersion darkfield condensers which require the use of a drop of immersion oil (some are designed to use water instead) establishing contact between the top of the condenser and the underside of the specimen slide. The immersion darkfield condenser has internal mirrored surfaces and passes rays of great obliquity and free of chromatic aberration, producing the best results and blackest background.

Perhaps the most widely used darkfield condenser is the paraboloid, consisting of a solid piece of glass ground very accurately into the shape of a paraboloid, as illustrated in Figure 5(b). Light incident upon the reflecting surface (between the glass and condenser housing in Figure 5(b)) of a paraboloid condenser will be focused at the focal point of the reflector. Most paraboloid condensers are cut to ensure that the focal point is slightly beyond the top of the condenser so that parallel light rays will be focused at a position that maximizes illumination of the specimen. The light stop at the bottom of the glass condenser serves to block central rays from reaching the specimen. Light rays that are reflected by the condenser are angled higher than the critical angle of reflection and converge at the principal focus of the condenser. The combination of a glass slide, mounting medium, and immersion oil (between the condenser and the microscope slide) complete the optical homogeneity of the paraboloid shape.

As discussed above, the dry darkfield condenser is useful for objectives with numerical apertures below 0.75 (Figure 5(a)), while the paraboloid and cardioid immersion condensers (Figures 1 and 5(b)) can be used with objectives of very high numerical aperture (up to 1.4). Objectives with a numerical aperture above 1.2 will require some reduction of their working aperture since their maximum numerical aperture may exceed the numerical aperture of the condenser, thus allowing direct light to enter the objective. For this reason, many high numerical aperture objectives designed for use with darkfield as well as brightfield illumination are made with a built-in adjustable iris diaphragm that acts as an aperture stop. This reduction in numerical aperture also limits the resolving power of the objective as well as the intensity of light in the image. Specialized objectives designed exclusively for darkfield work are produced with a maximum numerical aperture close to the lower limit of the numerical aperture of the darkfield condenser. They do not have internal iris diaphragms, however the lens mount diameters are adjusted so at least one internal lens has the optimum diameter to perform as an aperture stop.

Table 2 lists several properties of the most common reflecting high numerical aperture darkfield condensers. This table should be used as a guide when selecting condenser/objective combinations for use with high numerical aperture darkfield applications.

dark field condenser attachment

dark field condenser attachment lyme disease

 

Although this video clearly shows a spirochaetal shaped bacteria, it cannot identify what spirochaete it may be. To show that those bacteria are in fact Borrelia (the spirochaetal bacteria shown to cause Lyme borreliosis), proper DNA sequencing would have to occur.  From our perspective, if the person is sick and these are showing up in their blood, then treat the patient for a spirochaetosis while waiting for confirmation. Treatment is chosen within the patient/doctor discussion as to type of antibiotic and duration.  Infectious Disease Society of America (IDSA) guidelines are not recommended.  Current Canadian medical policy is to simply defer to the IDSA guidelines on matters of testing and treatment therefore we cannot recommend following Canadian medical policy in any province until patient expert’s opinion is given full and equal voice in the writing of Canadian medical policy relative to Lyme borreliosis.]

Slide 5

These video clips are from an experiment in which 11 friends provided a tiny amount of fingertip blood on a microscope slide.

All donors were met through patient support groups and have chronic illness.

8 of 11 have been ill for 20 years or longer.

9 have been diagnosed with M.E. or Chronic Fatigue Syndrome

10 of 11 had negative NHS tests for Lyme borreliosis – one was not tested.

9 had private tests that were positive.

These eleven donors represent a total of 235 years of illness and 170
years of lost productivity.

dark field condenser attachment

What dark field condenser attachment Applications

 

Viewing blood cells (biological darkfield microscope, combined with phase contrast)
Viewing bacteria (biological darkfield microscope, often combined with phase contrast)
Viewing different types of algae (biological darkfield microscope)
Viewing hairline metal fractures (metallurgical darkfield microscope)
Viewing diamonds and other precious stones (gemological microscope or stereo darkfield microscope)
Viewing shrimp or other invertebrates (stereo darkfield microscope)

In darkfield microscopy, contrast is created by a bright specimen on a dark background. It is ideal for revealing outlines, edges, boundaries, and refractive index gradients but does not provide a great deal of information about internal structure. Ideal subjects include living, unstained cells (where darkfield illumination provides information not visible with other techniques), although fixed stains cells can also be imaged successfully. Darkfield imaging is particularly useful in haematology for the examination of fresh blood. Non-biological specimens include minerals, chemical crystals, colloidal particles, inclusions and porosity in glass, ceramics, and polymer thin sections.

dark field condenser attachment

What is dark field condenser attachment?

 

All of us are quite familiar with the appearance and visibility of stars on a dark night, this despite their enormous distances from the Earth. Stars can be readily observed at night primarily because of the stark contrast between their faint light and the black sky.

Yet stars are shining both night and day, but they are invisible during the day because the overwhelming brightness of the sun “blots out” the faint light from the stars, rendering them invisible. During a total solar eclipse, the moon moves between the Earth and the sun blocking out the light of the sun and the stars can now be seen even though it is daytime. In short, the visibility of the faint star light is enormously enhanced against a dark background.

This principle is applied in darkfield (also called darkground) microscopy, a simple and popular method for making unstained transparent specimens clearly visible. Such objects often have refractive indices very close in value to that of their surroundings and are difficult to image in conventional brightfield microscopy. For instance, many small aquatic organisms have a refractive index ranging from 1.2 to 1.4, resulting in a negligible optical difference from the surrounding aqueous medium. These are ideal candidates for darkfield illumination.

Darkfield illumination requires blocking out of the central light which ordinarily passes through and around (surrounding) the specimen, allowing only oblique rays from every azimuth to “strike” the specimen mounted on the microscope slide. The top lens of a simple Abbe darkfield condenser is spherically concave, allowing light rays emerging from the surface in all azimuths to form an inverted hollow cone of light with an apex centered in the specimen plane. If no specimen is present and the numerical aperture of the condenser is greater than that of the objective, the oblique rays cross and all such rays will miss entering the objective because of their obliquity. The field of view will appear dark.

The darkfield condenser/objective pair illustrated in Figure 1 is a high-numerical aperture arrangement that represents darkfield microscopy in its most sophisticated configuration, which will be discussed in detail below. The objective contains an internal iris diaphragm that serves to reduce the numerical aperture of the objective to a value below that of the inverted hollow light cone emitted by the condenser. The cardioid condenser is a reflecting darkfield design that relies on internal mirrors to project an aberration-free cone of light onto the specimen plane.

When a specimen is placed on the slide, especially an unstained, non-light absorbing specimen, the oblique rays cross the specimen and are diffracted, reflected, and/or refracted by optical discontinuities (such as the cell membrane, nucleus, and internal organelles) allowing these faint rays to enter the objective. The specimen can then be seen bright on an otherwise black background. In terms of Fourier optics, darkfield illumination removes the zeroth order (unscattered light) from the diffraction pattern formed at the rear focal plane of the objective. This results in an image formed exclusively from higher order diffraction intensities scattered by the specimen.

The photomicrographs in Figure 2 illustrate the effects of darkfield and brightfield illumination on silica skeletons from a small marine protozoan (radiolarian) in a whole mount specimen. In ordinary brightfield, skeletal features of the radiolarian are not well defined and tend to be washed out in photomicrographs recorded either with traditional film or digitally captured. was taken in brightfield illumination with the condenser aperture diaphragm closed to a point where diffraction artifacts obscure some of the sample detail. This enhances specimen contrast at the expense of image distortion. Under darkfield illumination, more detail is present, especially in the upper portion of the organism, and the image acquires an apparent three-dimensional appearance. When a red filter is used in conjunction with a darkfield stop , the radiolarian takes on a colorful appearance that is more pleasing, although no additional detail is produced and there is even some reduction in image quality.

Specimens that have smooth reflective surfaces produce images due, in part, to reflection of light into the objective. In situations where the refractive index is different from the surrounding medium or where refractive index gradients occur (as in the edge of a membrane), light is refracted by the specimen. Both instances of reflection and refraction produce relatively small angular changes in the direction of light, allowing some to enter the objective. In contrast, some light striking the specimen is also diffracted, producing a 180-degree arc of light that passes through the entire numerical aperture range of the objective. The resolving power of the

dark field condenser attachment