How to dark field analysis Without dark field analysis

dark field analysis

dark field analysis

 

dark field analysis (dark-ground microscopy) describes microscopy methods, in both light and electron microscopy, which exclude the unscattered beam from the image. As a result, the field around the specimen (i.e., where there is no specimen to scatter the beam) is generally dark.

Light microscopy applications

In optical microscopy, dark-field describes an illumination technique used to enhance the contrast in unstained samples. It works by illuminating the sample with light that will not be collected by the objective lens and thus will not form part of the image. This produces the classic appearance of a dark, almost black, background with bright objects on it.

The light’s path

The steps are illustrated in the figure where an inverted microscope is used.
Diagram illustrating the light path through a dark-field microscope

Light enters the microscope for illumination of the sample.
A specially sized disc, the patch stop (see figure), blocks some light from the light source, leaving an outer ring of illumination. A wide phase annulus can also be reasonably substituted at low magnification.
The condenser lens focuses the light towards the sample.
The light enters the sample. Most is directly transmitted, while some is scattered from the sample.
The scattered light enters the objective lens, while the directly transmitted light simply misses the lens and is not collected due to a direct-illumination block (see figure).
Only the scattered light goes on to produce the image, while the directly transmitted light is omitted.

Advantages and disadvantages

dark field analysis is a very simple yet effective technique and well suited for uses involving live and unstained biological samples, such as a smear from a tissue culture or individual, water-borne, single-celled organisms. Considering the simplicity of the setup, the quality of images obtained from this technique is impressive.

The main limitation of dark-field microscopy is the low light levels seen in the final image. This means that the sample must be very strongly illuminated, which can cause damage to the sample. dark field analysis techniques are almost entirely free of artifacts, due to the nature of the process. However, the interpretation of dark-field images must be done with great care, as common dark features of bright-field microscopy images may be invisible, and vice versa.

While the dark-field image may first appear to be a negative of the bright-field image, different effects are visible in each. In bright-field microscopy, features are visible where either a shadow is cast on the surface by the incident light or a part of the surface is less reflective, possibly by the presence of pits or scratches. Raised features that are too smooth to cast shadows will not appear in bright-field images, but the light that reflects off the sides of the feature will be visible in the dark-field images.

Use in computing

dark field analysis has recently been used in computer mouse pointing devices, in order to allow an optical mouse to work on transparent glass by imaging microscopic flaws and dust on its surface.

dark field analysis combined with hyperspectral imaging

When coupled to hyperspectral imaging, dark-field microscopy becomes a powerful tool for the characterization of nanomaterials embedded in cells. In a recent publication, Patskovsky et al. used this technique to study the attachment of gold nanoparticles (AuNPs) targeting CD44+ cancer cells.

Transmission electron microscope applications

Dark-field studies in transmission electron microscopy play a powerful role in the study of crystals and crystal defects, as well as in the imaging of individual atoms.

Conventional dark-field imaging

Briefly, imaging involves tilting the incident illumination until a diffracted, rather than the incident, beam passes through a small objective aperture in the objective lens back focal plane. Dark-field images, under these conditions, allow one to map the diffracted intensity coming from a single collection of diffracting planes as a function of projected position on the specimen and as a function of specimen tilt.In single-crystal specimens, single-reflection dark-field images of a specimen tilted just off the Bragg condition allow one to “light up” only those lattice defects, like dislocations or precipitates, that bend a single set of lattice planes in their neighborhood. Analysis of intensities in such images may then be used to estimate the amount of that bending. In polycrystalline specimens, on the other hand, dark-field images serve to light up only that subset of crystals that are Bragg-reflecting at a given orientation.

Weak-beam imaging

Weak-beam imaging involves optics similar to conventional dark-field, but use of a diffracted beam harmonic rather than the diffracted beam itself. Much higher resolution of strained regions around defects can be obtained in this way.

Low- and high-angle annular dark-field imaging

Annular dark-field imaging requires one to form images with electrons diffracted into an annular aperture centered on, but not including, the unscattered beam. For large scattering angles in a scanning transmission electron microscope, this is sometimes called Z-contrast imaging because of the enhanced scattering from high-atomic-number atoms.

Digital dark-field analysis

This a mathematical technique intermediate between direct and reciprocal (Fourier-transform) space for exploring images with well-defined periodicities, like electron microscope lattice-fringe images. As with analog dark-field imaging in a transmission electron microscope, it allows one to “light up” those objects in the field of view where periodicities of interest reside. Unlike analog dark-field imaging it may also allow one to map the Fourier-phase of periodicities, and hence phase gradients, which provide quantitative information on vector lattice strain.

dark field analysis

What is Disadvantages of dark field analysis?

A dark field microscope can result in beautiful and amazing images; this technique also comes with a number of disadvantages.

First, dark field images are prone to degradation, distortion and inaccuracies.
A specimen that is not thin enough or its density differs across the slide, may appear to have artifacts throughout the image.
The preparation and quality of the slides can grossly affect the contrast and accuracy of a dark field image.
You need to take special care that the slide, stage, nose and light source are free from small particles such as dust, as these will appear as part of the image.
Similarly, if you need to use oil or water on the condenser and/or slide, it is almost impossible to avoid all air bubbles.
These liquid bubbles will cause images degradation, flare and distortion and even decrease the contrast and details of the specimen.
Dark field needs an intense amount of light to work. This, coupled with the fact that it relies exclusively on scattered light rays, can cause glare and distortion.
It is not a reliable tool to obtain accurate measurements of specimens.
Finally, numerous problems can arise when adapting and using a dark field microscope. The amount and intensity of light, the position, size and placement of the condenser and stop need to be correct to avoid any aberrations.

Dark field has many applications and is a wonderful observation tool, especially when used in conjunction with other techniques.

However, when employing this technique as part of a research study, you need to take into consideration the limitations and knowledge of possible unwanted artifacts.

dark field analysis

What Makes Up Healthy Blood?

What one sees in the mobile situation are the usual red blood cells, white blood cells, plasma—and what is floating in the plasma. Microbial activity, undigested food, fungi, and crystals are all apparent as is the capacity of the red blood cells to circulate and the white blood cells to devour morbid matter.

(Live Blood Examination in the Darkfield according to Prof. Dr. G. Enderlein)
dark field analysis or Live Blood Analysis is a way of studying live whole blood cells under a specially adapted microscope that projects the dynamic image onto a video screen. This allows you to view your inner terrain. Digestive, eliminative and immune functions can be assessed as well as the presence of bacteria and other micro-organisms.

The darkfield microscopic examination of the freshly taken live blood is one of the most important examinations of the holistic medicine applied at the Centre. It enables us to view the inner terrain (milieu) and to examine the functions of the red blood cells. It also shows the evolutionary stages of the smallest proteins (endobionts) which are found in every human body. We are also able to see any developed structures such as bacteria, virus and fungus. The darkfield examination shows the state of the blood cells, endobionts and the plasma in a functional and structural way, making bacterial processes and fungal pre-stages in the blood clearly visible.

The darkfield examination is most suitable for the evaluation of chronic diseases; for children who are prone to infections; for recurrent bacterial problems; for candida and other fungal problems and also to answer questions concerning chronic problems of toxicity (e.g. amalgam disturbances).

dark field analysis

What is dark field analysis?

Similar to a bright field but it is modified by a dark field stop just below the source. The dark field stop is just  the condenser, and blocks the light in the center of the lightsource so that the only light that goes through is around the edges. That light is then bent by the condenser and diffacts off the specimen. None of the light goes directly from the light source into the objective, so if there is no specimen, the image will be very dark. The specimen in this method will be illuminated against a black background.
A dark field microscope is useful because it increases the contrast of the image and does not use stains. The lack of staining means that it can be used on live specimens and that one can observe the motility of the organism as well as its correct morphology. Usually, the stains and enzymes used in labs can distort the shape of the organism, but that isn’t an issue with dark field microscopy. This method can also be used to see organisms that are hard to stain, such as Treponema pallidum, spirochetes, and mycoplasma.The one downside is that it’s not possible to see the inclusions, or internal details of the cell

dark field analysis

What is Basics of dark field analysis ?

A darkfield microscope is a magnifying device in which objects are lit at a very low angle from the side so that the background appears dark and the objects show up against this dark background. Hence the descriptor “darkfield”.

Darkfield is therefore the method whereby the sample being viewed is actually in front of a dark background and light is being angled onto the sample from the sides.

Under phase contrast conditions, the light coming through the specimen is shifted into two beams, one slightly out of phase with the other. This gets a little complicated to explain easily, but as far as equipment concerns, you need two matched items in order to get phase contrast.

One needs a phase annulus, and the matching lens objective. For instance, if you want 40x magnification phase contrast microscopy, you need a 40x phase lens, and a matched 40x phase annulus. If you want 100x phase, you need the 100x lens and the matched 100x phase annulus.

Both the techniques of darkfield and phase contrast allow nearly invisible microorganisms within the blood to be “lit up” and seen. It also clearly delineates the blood cells. This method is in contrast to the standard microscope “brightfield” conditions where light shines directly through the viewed sample, and invisible particles remain invisible.