what is dark field microscopy?

What is dark field microscopy ?

what is dark field microscopywhat is dark field microscopy what is dark field microscopy what is dark field microscopy

What is a Dark Field Microscopy? The dark field microscopic examination of freshly collected, vital blood is a pillar of the Paracelsus Clinica al Ronc holistic medical diagnosis. It provides information on the internal milieu and function of the blood cells, as well as the amount and development of endobionts, from which microorganisms and more sophisticated structures, such as bacteria, fungi, and viruses, develop.dark field microscopy is a transmitted light technique that uses oblique light to illuminate the sample. Light that does not impinge on the sample is not collected by the objective and results in a dark background. Light that interacts with the sample is scattered (refracted, reflected, and/or diffracted) and is “bent” toward the objective collection angle. This light is collected by the objective and is seen as light spots or areas (resulting from scattered light) on a dark background. Contrast is therefore generated and the sample visualized.dark field microscopy is provided to the sample by a specialized condenser. The simplest DF condenser has a Stop, or Annulus illuminating ring (A). Here, an opaque circle obscures the central portion of the condenser light path. This allows only light in a ring to illuminate the sample.

what is dark field microscopy

dark field microscopy

what is dark field microscopy-The diameter of the central stop, and thus illuminating annulus, is such that the angle of light is greater than the collecting angle of the objective. Thus without a sample, no light is collected by the objective. This kind of DF stop is useful only for low magnification objectives (<20x).For higher magnification objectives, modifications of the Annular Stop are: B: Immersion paraboloid; C: immersion double mirror concentric; D: cardioid concentric. Gray cone represents the light reflected and refracted from the specimen and collected by the objective. Hatched areas represent glass. Light blocking stops (s) limit light transmission to a hollow cone. i: Immersion oil.; r: reflecting surfaces. (Ruzin,1999).

 

what is dark field microscopy-Brightfield microscopy uses light from the lamp source under the microscope stage to illuminate the specimen. This light is gathered in the condenser, then shaped into a cone where the apex is focused on the plane of the specimen. In order to view a specimen under a brightfield microscope, the light rays that pass through it must be changed enough in order to interfere with each other (or contrast) and therefore, build an image. At times, a specimen will have a refractive index very similar to the surrounding medium between the microscope stage and the objective lens. When this happens, the image can not be seen. In order to visualize these biological materials well, they must have a contrast caused by the proper refractive indices, or be artificially stained. Since staining can kill specimens, there are times when dark field microscopy is used instead.

In dark field microscopy the condenser is designed to form a hollow cone of light (see illustration below), as apposed to brightfield microscopy that illuminates the sample with a full cone of light. In dark field microscopy, the objective lens sits in the dark hollow of this cone and light travels around the objective lens, but does not enter the cone shaped area. The entire field of view appears dark when there is no sample on the microscope stage. However, when a sample is placed on the stage it appears bright against a dark background. It is similar to back-lighting an object that may be the same color as the background it sits against – in order to make it stand out.

what is dark field microscopy-Use scissors or (preferably) a brass cork borer to cut a set of stops matched to all of the objectives, and glue them to a sturdy sheet of clear acetate or glass. The acetate or glass substrate should be easily mountable onto the underside of the substage condenser, either through a filter holder or by other means, such as adhesive tape. Alignment of the stop can be done by observing it through a Bertrand lens or removing the eyepiece and viewing through a phase telescope while adjusting the condenser centering screws.

what is dark field microscopy what is dark field microscopy what is dark field microscopy

dark field microscopy at High Magnifications

what is dark field microscopy-For more precise work and blacker backgrounds, you may choose a condenser designed especially for darkfield, i.e. to transmit only oblique rays. There are several varieties: “dry” darkfield condensers with air between the top of the condenser and the underside of the slide–and immersion darkfield condensers which require the use of a drop of immersion oil (some are designed to use water instead) establishing contact between the top of the condenser and the underside of the specimen slide. The immersion darkfield condenser has internal mirrored surfaces and passes rays of great obliquity and free of chromatic aberration, producing the best results and blackest background.

what is dark field microscopy-Perhaps the most widely used darkfield condenser is the paraboloid, consisting of a solid piece of glass ground very accurately into the shape of a paraboloid, as illustrated in Figure 5(b). Light incident upon the reflecting surface (between the glass and condenser housing in Figure 5(b)) of a paraboloid condenser will be focused at the focal point of the reflector. Most paraboloid condensers are cut to ensure that the focal point is slightly beyond the top of the condenser so that parallel light rays will be focused at a position that maximizes illumination of the specimen. The light stop at the bottom of the glass condenser serves to block central rays from reaching the specimen. Light rays that are reflected by the condenser are angled higher than the critical angle of reflection and converge at the principal focus of the condenser. The combination of a glass slide, mounting medium, and immersion oil (between the condenser and the microscope slide) complete the optical homogeneity of the paraboloid shape.

what is dark field microscopy-As discussed above, the dry darkfield condenser is useful for objectives with numerical apertures below 0.75 (Figure 5(a)), while the paraboloid and cardioid immersion condensers (Figures 1 and 5(b)) can be used with objectives of very high numerical aperture (up to 1.4). Objectives with a numerical aperture above 1.2 will require some reduction of their working aperture since their maximum numerical aperture may exceed the numerical aperture of the condenser, thus allowing direct light to enter the objective. For this reason, many high numerical aperture objectives designed for use with darkfield as well as brightfield illumination are made with a built-in adjustable iris diaphragm that acts as an aperture stop. This reduction in numerical aperture also limits the resolving power of the objective as well as the intensity of light in the image. Specialized objectives designed exclusively for darkfield work are produced with a maximum numerical aperture close to the lower limit of the numerical aperture of the darkfield condenser. They do not have internal iris diaphragms, however the lens mount diameters are adjusted so at least one internal lens has the optimum diameter to perform as an aperture stop.

what is dark field microscopy what is dark field microscopy what is dark field microscopy

what is dark field microscopy-Table 2 lists several properties of the most common reflecting high numerical aperture darkfield condensers. This table should be used as a guide when selecting condenser/objective combinations for use with high numerical aperture darkfield applications.
High Numerical Aperture Darkfield Condenser Specifications
Condenser Type Hollow Cone
Numerical Aperture Objective Maximum
Numerical Aperture Number of Reflecting
Surfaces Optical Corrections
Paraboloid 1.00-1.40 0.85 1 Parabolic Achromatic
Cardioid 1.20-1.30 1.05 1 Spherical
1 Cardioidal Achromatic/
Aplanatic
Bicentric 1.20-1.30 1.05 1 Cardioidal
1 Spherical Aplanatic
Bispheric 1.20-1.30 1.05 2 Spherical Aplanatic
Cassegrain 1.40-1.50 1.30 1 Aspheric
1 Spherical Aplanatic
Spot Ring
(Bicentric) 1.40-1.50 1.30 2 Spherical Aplanatic
Nelson
Cassegrain 1.30-1.45 1.20 1 Aspheric
1 Spherical Aplanatic

what is dark field microscopy-The condensers illustrated in Figure 5 are designed specifically to produce oblique hollow light cones of high numerical aperture for dark field microscopy. In both instances, the upper surface of the condenser is planar and perpendicular to the optical axis of the microscope. The condenser on the left (Figure 5(a)) is designed to be used “dry” with no oil between the condenser and the underside of the microscope slide. In contrast, the paraboloid condenser in Figure 5(b) is intended to be “oiled” to the bottom of the microscope slide, directly underneath the specimen. Omission of immersion oil when using this condenser (or any of the other condensers listed in Table 2) will preclude any light from reaching the specimen. The oblique hollow cone of light rays emitted by these condensers cannot emerge from the top lens without oil and will be totally reflected back into the condenser. Light emitted from the illumination source is reflected at the mirrored glass surfaces within the interior of the condensers and exits the top of the condensers at much higher angles of inclination than the critical angle (approximately 41 degrees) at which total reflection occurs for passage of light from glass to air. In the situation of the oiled paraboloid condenser (Figure 5(b) and the condensers in Table 2) where the refractive index of the condenser glass, immersion oil, and glass slide are equal, light emitted from the condenser passes through the specimen unrefracted by glass-air interfaces.
Hollow Light Cone Numerical Aperture

what is dark field microscopy what is dark field microscopy what is dark field microscopy

Use this tutorial to visualize how the hollow cone of light changes with numerical aperture in reflecting darkfield condensers.
Start Tutorial

what is dark field microscopy-Reflecting high numerical aperture condensers listed in Table 2 cover a wide range of designs used to produce the oblique hollow cone of light necessary for high-magnification dark field microscopy. The paraboloid darkfield condenser has been discussed in detail above. Another very useful design is the cardioid condenser that is illustrated in Figure 1. This condenser design utilizes a mirrored hemisphere in the center of the condenser that serves as both a light stop and a reflector to direct light onto a second reflecting surface shaped to resemble a cardioid of revolution, from which the condenser derives its name. The combination of spherical and cardioid reflecting surfaces produces a condenser that is free from coma and both spherical and chromatic aberration. There are several technical drawbacks to using a condenser of such high numerical aperture. The cardioid condenser is very sensitive to alignment and must be carefully positioned to take advantage of the very sharp cone of illumination, making it the most difficult darkfield condenser to use. In addition, the condenser produces a significant amount of glare, even from the most minute dust particles, and the short focal length may result in poor illumination on objects that exceed a few microns in size or thickness. When choosing microscope slides for quantitative high-magnification dark field microscopy, make certain to select slides made from a glass mixture that is free of fluorescent impurities.

what is dark field microscopy-High numerical aperture reflecting condensers (Figures 1, 5, 6 and Table 2) with dark field microscopy provide the method of choice for observing and photographing collections of very small particles or colloidal suspensions, even when the particle diameter is significantly lower than the limit of resolution for the objective. This is due to light diffracted by the particles, which passes through the objective and becomes visible as bright diffraction disks. Each particle is visible as a minute diffraction disk, provided the lateral distance between adjacent particles is greater than the limit of resolving power of the objective. As illumination intensity is increased, the optical difference between minute diffracting particles and their background increases. Simultaneously, even smaller particles (detectable solely by their ability to scatter light) now diffract enough light to become visible and suspended particles can be seen even when their diameters are smaller than 40 nanometers, which is about one-fifth the 200 nanometer resolution limit with oil immersion objectives of the highest numerical aperture. In biological applications, the movements of living bacterial flagella that average about 20 nanometers in diameter (too small to be seen in brightfield or DIC illumination) can be observed and photographed using high numerical aperture darkfield condensers.

what is dark field microscopy-Careful attention should be paid to the details of oiling a high numerical aperture condenser to the bottom of the specimen slide. It is very difficult to avoid introduction of tiny air bubbles into the area between the condenser top lens and the bottom of the microscope slide, and this technique should be practiced to perfection. Air bubbles will cause image flare and distortion, leading to a loss of contrast and overall image degradation. Problems are also encountered when using microscope slides that are either too thick or too thin. Many darkfield condensers contain the range of usable slide thickness inscribed directly on the condenser mount. If the slide is too thick, it is often difficult to focus the condenser without resorting to a higher viscosity immersion oil. On the other hand, slides that are too thin have a tendency to break the oil bond between the condenser and the slide. It is a good idea to purchase precision microscope slides of the correct thickness to avoid any of the problems mentioned above.
Darkfield Condenser Adjustment

Explore how alignment and configuration of a darkfield condenser affects image quality.
Start Tutorial

A unique situation arises when specimens immersed in aqueous medium are being imaged using a high numerical aperture darkfield condenser. Under these conditions the refractive index of the aqueous solution limits the angle of inclination under which light can pass from the glass microscope slide (n = 1.515) into the water (n = 1.336) surrounding the specimen. The maximum numerical aperture of light passing from glass to water is given by the following equation:

NA (illumination) = 1.555 × sin(i) = 1.336 × sin(90°)

and because sin(90°) = 1

NA (illumination) = 1.336

what is dark field microscopy-Even though reflecting darkfield condensers designed for oil immersion are listed with upper limits of numerical aperture as high as 1.50 (see Table 2), light contributing to the illumination of specimens in aqueous media must have a numerical aperture no greater than 1.336, reducing the effective upper limit of dark field microscopy. In the case of specimens immersed in liquids of higher refractive index, the effective upper limit of the numerical aperture of dark field microscopy can approach a maximum of 1.50, although this is difficult to achieve in practice.

what is dark field microscopy what is dark field microscopy

High numerical aperture condensers, whether intended for use dry or with oil, must be accurately centered in the optical path of the microscope to realize optimum performance. To achieve this, many darkfield condensers are built with a small circle engraved onto the upper surface to aid in centering the condenser. Centering is performed with a low power (10x-20x) objective by imaging the engraved circle and using the condenser centering screws to ensure the circle (and condenser) are correctly centered in the optical path. For more detailed information about microscope alignment for dark field microscopy, consult our section on darkfield microscope configuration elsewhere in the microscopy primer.

what is dark field microscopy-In general, objects imaged under proper conditions of dark field microscopy are quite spectacular to see (e.g. try a drop of fresh blood in darkfield). Often specimens containing very low inherent contrast in brightfield microscopy shine brilliantly in darkfield. Such illumination is best for revealing outlines, edges, boundaries, and refractive index gradients. Unfortunately, dark field microscopy is less useful in revealing internal details.

what is dark field microscopy-Other types of specimens, including many that are stained, also respond well to illumination under darkfield conditions. Figure 7 illustrates darkfield photomicrographs of three types of specimen, all of which produce good contrast in both brightfield and dark field microscopy. Details in the body of the deer tick (Ixodes demmini) shown in Figure 7(a) can be washed out in brightfield, unless the condenser aperture is stopped down to maximize contrast. However, in darkfield, most of the specimen detail in the tick becomes visible and can be easily captured on film. The heavily stained helminth trematode (Echinostoma revolutum, Figure 7(b)) also reveals considerably more detail when illuminated under darkfield conditions, as does the silkworm trachea and spiracle illustrated in Figure 7(c). In addition to the examples presented above, a number of other specimens can also be viewed and photographed under both brightfield and dark field microscopy to achieve the desired effects.

what is dark field microscopy-During the first half of the Twentieth Century, dark field microscopy had a very strong following and much effort was expended in optimizing darkfield condensers and illuminators. This intense interest slowly began to fade with the emergence of more advanced contrasting-enhancing techniques such as phase contrast, differential interference contrast, and Hoffman modulation contrast. Recently, a renewed interest in transmitted dark field microscopy has arisen due to its advantages when used in combination with fluorescence microscopy.

Dark field microscopy is still an excellent tool for both biological and medical investigations. It can be effectively used at high magnifications to photograph living bacteria, or at low magnifications to view and photograph cells, tissues, and whole mounts. Marine biologists continue to use dark field microscopy at low powers to observe and record data about fresh and salt water organisms such as algae and plankton.

 

 